Supertherm
Independant testing
results
|
|
|
ASTM
Test Listing (pdf
- 58kb)
Revised
10-09-01 listing of ASTM G53, ASTM E96, ASTM D522,
ASTM D412, ASTM D1653, ASTM E 84-89, ASTM E 119, ASTM E 119, ASTM C
177, ASTM C 411, ASTM E1269, ASTM E1461-92, ASTM D1654, ASTM D3274,
ASTM D4060, ASTM E-903-96, ASTM E-1918, NHB 8060.1B/C TEST 1, NHB 8060.
1C, TEST 7, JIS A-5759, USDA, M0729, BOCA Section 723.2, BOCA Section
723.3, BOCA Section 803.2, BOCA 1998 International Mechanical Code Section
604.3.
Exposure to UV, elevated temperature and humidity - passed
Water Vapour
transmission - passed
Resistance
to cracking on metal or rubber type materials - passed
Tensile Strength
- passed
Flame Spread
and smoke generation - passed
Structure Steel
Fire Curve - passed
Thermal conductivity
test - passed
Salt spray
only - 450 hours - passed
Fungal growth
or soil and dirt accumulation on paint film - passed
Abrasion resistance
of organic coatings - passed
Toxic offgassing
- none - passed
Reflectivity
of sunlight on window or coating film - passed
Environmentally
safe and safe for use around animals - passed
Approved and
accepted as energy star partner for saving energy - passed
|
|
|
ASTMB117
Salt Spray Tests (pdf
- 40kb)
Northwest
Testing Laboratories, Salt Spray Corrosion Tests.
|
|
|
ASTM
C236:
For R
Value with Fiberglass Batt insulation
(pdf
- 1,500kb)
R19.3 and R28.5 Rating given to Supertherm in a test by VTEC
Laboratories. Supertherm proved to be 240% better than fiberglass
insulation in a test designed to favor fiberglass. Fiberglass Batt insulation
is only tested at 70F and with no moisture in order to give it's highest
rating. Supertherm performs equaly from -50 to 300F and is never
affected by moisture.
|
|
|
Sound
Proof Test (pdf
- 531kb)
Sound
Testing performed by Hot-Cold Air and Fire Control by Pat Saulson, PhD.
Sound reduced on average 50% for interior walls and 23% for exterior
walls.
|
|
|
ASTMD-3273-82T
(pdf 44kb)
Buckman
Laboratories International, Technical Service Laboratory Report. Resistance
to growth of mould in severe mould environments.
|
|
|
ASTMD-3274
(pdf - 38kb)
Buckman
Laboratories International, Technical Service Laboratory Report, Table.
Fungal growth or soil and dirt accumulation.
|
|
|
ASTM
Tests (pdf
- 58kb)
ASTM
G53, ASTMD1653, ASTMD4060, ASTME96, ASTMD522, ASTMD412
Visual effect
of UV exposure - passed
Water vapour
permeability on organic coatings
Abrasion resistance
on organic coatings
Water vapour
transmission on materials
Mandrel Bend
test
Tensile properties
|
|
|
BOCA
Report
(pdf - 91kb)
BOCA International Evaluation Report. US National Building Code 1999
- endorsement of Supertherm.
|
|
|
Chicken
House Test (pdf
- 91kb)
Perimeter
Industries Test Chicken House Roof - Cold storage facility for Jacks
Hamburgers and Subway Foods, Cagle Foods.
|
|
|
Coke
Pusher Cab
(pdf - 251kb)
Sloss Industries Testing Documentation for Perimeter Industries, Coke
Pusher Cabs Test, Stand Pipe Test, Steam Pipe Test, Oven Door Plug Test,
Leveling Door Castings, Summary and Recommendations.
|
|
|
Ecopetrol
Test (pdf
- 80kb)
Ecopetrol
Certification. Use of Supertherm instead of Aluminium foil for
insulation.
|
|
|
Emittance
Test
(pdf - 87kb)
Tennesse
Tech Emittance Test.
|
|
|
Fire
Tests (pdf
- 638kb)
Fire
Safe of Central Florida Test, Flash Fire, Test 1, Test 2, Evaluation
of Thin Coatings for Thermal Transfer Properties at Elevated Temperatures,
ASTM E84-89a Surface Burning Characteristics.
|
|
|
Incinerator
Test (pdf
- 290kb)
Hazardous
Waste Incineration Meeting, Coating Developed for Aerospace Industry
Potects Hazardous Waste Incinerators.
|
|
|
Japan
Applications Tests (pdf
- 2,194kb)
Reduction
of Heat, Reduction in Room Temperature, Table of Presentation of Written
Estimates for 1996 for Supertherm, Two Examples of Supertherm
at Work, Cosmo Trade & Service Co. Test, Recap of latest Testing
Performed by Major Companies in Japan.
|
|
|
Jet
Engine Thruster Test (pdf
- 250kb)
Jet
Engine Reverse Thruster Test, (see graphs in pdf).
|
|
|
NASA
Flamability Test (pdf
- 262kb)
NASA
Space Flight Center Testing of Supertherm.
|
|
|
US
Navy
(pdf
- 4,020kb)
US Navy Testing and Approval, SP 2001F , High-Temperature Insulative
Coating. SP2001F protects aluminium from melting. Rust Grip
rating at 6750 psi surface tensile strengh (harder than concrete on
some surface metals). Epoxotherm used to prevent condensation
air ducting throughout ship. Sound dampened by 68% on hulls of ships.
Use of Supertherm or Hot Surface Coating in the engine
room to hide heat signature from being detected by enemy missiles. This
means a missile with heat seeking capabilities cannot hit the heart
of a ship.
|
|
|
Ontario
Hydro Test (pdf
- 193kb)
Supertherm
Results & Application Test Patches for Ontario Hydro, Projected
Savings over the 10 years of Operation, Operating Temperature, Optimum
Operating Temperature, ability to save and make money.
|
|
|
Omega
BTU Gun Test (pdf
- Size 68kb)
Energy
Report - Using Omega OS-652 Energy Meter (BTU GUN), BTU Data, Calculations-Roof,
Calculations-Coolers, R-Value using BTU Gun.
|
|
|
Poultry
House Test (pdf
- 119kb)
Supertherm
on Poultry Houses, Avian Sciences Univ. of California at Davis report.
Reduce death rate on chickens by 75%, increased weight of chickens meaning
better sale and over 20 years saving from reinsulation and labour costs.
|
|
|
Produce
Transport Application (pdf
- 81kb)
Merrimac
Maintenance Products Company, Newsletter #6.
|
|
|
Supertherm
On Building (pdf
- 78kb)
Chicago
Visit and Testing, Building #1, Building #2, Ambient Temperatures, Equipment,
Wall Construction & Application, Wall readings, Results, Conditions.
|
|
|
Supertherm
Vs Other Coatings
(pdf
- 61kb)
Temperature
of Coatings & Other Materials in Sunlight.
|
|
|
Thermographic
Test
(pdf - 4,536kb)
Supertherm
Thermography Test Result, Characteristics, Heat Insulation Tests for
Supertherm, Cost Comparison for Air Conditioning.
|
|
|
Thermophysical
Tests
(pdf - 901kb)
Thermal
Conductivity, ASTM C 177, ASTM E1461-92, Thermophysical Properties Research
Laboratory, Table 1, Table 2, Table 3, Table 4, Table 5.
|
|
|
Test
Reports Comments (pdf
- 642kb)
R-Factor vs RE-Factor, Heat Build-up and Condensation in Grain Storage
Bins, USA Approval, K-Factor Rating, Supertherm vs Radiant Reflective
Surfaces, Supertherm vs Other Insulation.
|
|
|
USA
Dept Agriculture
(pdf - 60kb)
United